HSC Chemistry Year 12 – Every Experiment, Organised by the Syllabus
Scope: Experiments only (the "conduct…" dot points of the 2017 NESA Stage 6 Chemistry syllabus). Secondary-source and modelling tasks are left out.
Source: The methods are condensed and rewritten in my own words from the investigations in Chemistry in Focus Year 12, with equipment and quantities built in. Where the syllabus gives an "e.g." and the book left the method open, I wrote a standard version. Check anything that differs from what your class did.
How to use each entry
Each experiment has: the syllabus dot point it satisfies, aim, hypothesis, variables, method (with quantities), diagram checklist, risk assessment (hazard → precaution → why), results/analysis, and evaluation.
The exam rules for any "outline an investigation" question
- Put equipment, substances and realistic quantities inside the method steps. Don't write a separate materials list.
- Realistic scale: 2 mL of reagent in a test tube, 20.00 mL pipetted aliquots, 100 mL beakers. A guess like 50 mL in a test tube gets no mark.
- Diagrams: pencil, ruler, fully labelled, with the substances and their quantities drawn in.
- Risk assessment: hazard → precaution → why the precaution works.
- Aims never start "to prove". Hypotheses are supported or not supported.
Terms examiners expect you to use correctly
- Independent variable: what you change. Dependent variable: what you measure. Controlled variables: what you keep constant, and how.
- Valid: a fair test that answers the question (one variable changed, others controlled).
- Reliable: repeat trials give consistent results.
- Accurate: close to the true value. Precise: repeat values close together.
- Random error gives scatter (reduce it by repeating). Systematic error gives a constant offset (calibration, parallax, heat loss).
- Uncertainty: analogue = ±½ smallest division; digital = ± one whole division.
- Improving reliability: repeat trials and average. Improving validity: control more variables. Improving accuracy: better equipment or calibration.
MODULE 5 – EQUILIBRIUM AND ACID REACTIONS
Experiment 1 – Reversibility of chemical reactions
Syllabus: Conduct practical investigations to analyse the reversibility of chemical reactions, e.g. CoCl₂ hydrated and dehydrated; Fe(NO₃)₃ and KSCN; burning magnesium; burning steel wool.
Aim: To observe a range of reactions and decide whether each is reversible.
Hypothesis: The cobalt(II) chloride and iron(III) thiocyanate reactions are reversible, while burning magnesium and steel wool are not.
Variables: Independent: the reaction type or the change applied. Dependent: observed colour or mass. Controlled: quantities of reagents, same oven temperature.
Method
- CoCl₂ paper: lay a 55 mm filter paper on a watch glass. Add 0.1 mol L⁻¹ cobalt(II) chloride dropwise with a dropper until the paper is covered (pink). Dry it in an oven at 35°C overnight and record the colour (blue). Add distilled water dropwise until covered and record the colour (pink). Dry it again and record.
- Iron(III) thiocyanate: pipette 1 mL of 0.1 mol L⁻¹ Fe(NO₃)₃ and 1 mL of 0.1 mol L⁻¹ KSCN into a 25 mL measuring cylinder. Make up to 20 mL with distilled water (pale red). Pour 5 mL into each of two test tubes, keeping one as a reference. To the other add 1 mL of 0.1 mol L⁻¹ fluoride solution (the red fades as Fe³⁺ is removed), then add 2 mL of 0.1 mol L⁻¹ Fe(NO₃)₃ (the red returns).
- Burning magnesium: hold a 5 cm piece of sandpapered magnesium ribbon in brass tongs over a heatproof mat. Ignite it with a gas lighter, looking away from the flame. Record the product (white powder). Add a few drops of water to the cooled product and try to regenerate the metal by heating.
- Burning steel wool: weigh a 5 × 5 cm piece of steel wool (±0.01 g) on a heatproof mat. Ignite it with the lighter, let it cool, and reweigh.
Diagram: watch glass with filter paper and dropper in a drying oven; test-tube rack with labelled tubes and volumes; tongs holding Mg over a heatproof mat; balance with steel wool.
Risk assessment
- Cobalt(II) chloride is toxic to humans and wildlife. Use a dropper and brass tongs and wear gloves, so there is no skin contact or ingestion and no spills into waterways.
- Fluoride and thiocyanate solutions are harmful. Wear gloves and goggles and collect waste in the waste bottle, because they are toxic if absorbed.
- Burning magnesium emits intense white light and UV. Look away or wear tinted goggles, because the light can damage the retina.
- Hot metal burns. Use tongs and a heatproof mat, because direct contact gives burns.
Results and analysis
- CoCl₂ paper is pink when hydrated, blue when dry, and pink again with water, so the reaction is reversible: [Co(H₂O)₆]²⁺ (pink) ⇌ CoCl₂ (blue) + 6H₂O.
- Fe³⁺ + SCN⁻ ⇌ FeSCN²⁺ (red): adding F⁻ removes Fe³⁺ and the red fades; adding Fe³⁺ restores it. The reaction is reversible.
- Mg burns to form MgO (2Mg + O₂ → 2MgO) and steel wool burns with a mass increase because iron combines with oxygen from the air. Neither reverses on adding water or cooling, so they are not reversible. They run in open systems and the products can't regenerate the reactants.
Evaluation: Use the same quantities each time. Photograph the colours for a record. Repeat for reliability. The mass gain of steel wool is small, so use a balance with ±0.01 g or better.
Experiment 2 – Modelling dynamic equilibrium
Syllabus: Model static and dynamic equilibrium and analyse the differences between open and closed systems.
Aim: To model a reversible reaction and determine when dynamic equilibrium is reached.
Hypothesis: The volumes in the two cylinders will stop changing, because the forward and reverse transfer will become equal.
Variables: Independent: number of cycles. Dependent: volume in each cylinder. Controlled: cylinder size, pipette sizes, technique.
Method
- Label two identical 100 mL measuring cylinders A and B. Fill A with 100 mL of water; B is empty.
- Place a 10 mL graduated pipette upside down in A so the wide end is under water and let it fill. Seal the narrow tip with a thumb and transfer the contents to B (forward reaction).
- Do the same with a 5 mL graduated pipette from B back to A (reverse reaction). That is one cycle.
- Record the volume in each cylinder after every cycle for 50 cycles.
- Plot volume against cycle number for A and B on the same axes.
Diagram: two cylinders A and B with arrows labelled "forward: 10 mL pipette" and "reverse: 5 mL pipette", and volumes marked.
Risk assessment
- Glass can break and cut. Keep cylinders and pipettes back from the bench edge and lay pipettes where they can't roll, so they don't fall and shatter.
Results and analysis: The volumes change quickly at first, then stay constant. The graph lines level off. Compare the slopes of the first five cycles with the last five. At equilibrium the forward and reverse transfers are equal, so there is no net change, but the transfer continues (dynamic). This models a closed system. Static equilibrium would mean no transfer at all.
Evaluation: Compared with a real chemical reaction, the model uses fixed volumes rather than rates that depend on concentration. Water level affects how much each pipette collects. Repeat and use the same operator for consistency.
Experiment 3 – Effect of concentration on equilibrium (Fe³⁺ + SCN⁻ ⇌ FeSCN²⁺)
Syllabus: Investigate the effects of concentration… on a system at equilibrium and explain with Le Chatelier's principle, e.g. iron(III) thiocyanate and varying concentration of ions.
Aim: To observe the effect of changing concentration on a system at equilibrium.
Hypothesis: Increasing [Fe³⁺] or [SCN⁻] will shift the equilibrium right (darker red); removing Fe³⁺ will shift it left (paler).
Variables: Independent: the ion added. Dependent: colour of the solution. Controlled: volume of equilibrium mixture (about 5 mL), volume of each addition (1 mL), temperature.
Method
- Pour 1 mL of 0.1 mol L⁻¹ iron(III) chloride into a 10 mL measuring cylinder and 1 mL of 0.1 mol L⁻¹ ammonium thiocyanate into another. Pour both into a 25 mL measuring cylinder and make up to 20 mL with distilled water.
- Label four test tubes A–D and pour equal portions (about 5 mL) of this solution into each. Keep A as the reference.
- Add 1 mL of 0.1 mol L⁻¹ FeCl₃ to B, 1 mL of 0.1 mol L⁻¹ NH₄SCN to C, and 1 mL of fluoride solution (calcium fluoride in the book) to D, which removes Fe³⁺.
- Photograph each tube against A on a white background.
Diagram: rack with four test tubes A–D, each with 5 mL and the 1 mL addition labelled.
Risk assessment
- Splashes can irritate the eyes and skin. Wear goggles and wash hands afterwards, because the solutions are mildly harmful.
- FeSCN²⁺ is harmful to aquatic life. Collect waste in a waste bottle, not the sink, so it doesn't reach waterways.
Results and analysis: B and C are darker red than A; D is paler. Fe³⁺ + SCN⁻ ⇌ FeSCN²⁺. Adding a reactant increases the rate of the forward reaction (more frequent collisions), so the system shifts right until a new equilibrium is reached. Removing Fe³⁺ lowers the forward rate, so the reverse reaction dominates and the system shifts left.
Evaluation: Colour comparison is qualitative. Using a colourimeter would give quantitative data. Keep the volumes identical for a fair comparison.
Experiment 4 – Effect of temperature on equilibrium ([Co(H₂O)₆]²⁺ ⇌ [CoCl₄]²⁻)
Syllabus: Investigate the effects of temperature… e.g. heating cobalt(II) chloride hydrate.
Aim: To observe the effect of changing temperature on a system at equilibrium.
Hypothesis: Heating will turn the solution blue (shift right) and cooling will turn it pink (shift left), showing the forward reaction is endothermic.
Variables: Independent: temperature. Dependent: colour. Controlled: concentration and volume of the cobalt solution, amount of chloride.
Method
- Dissolve a pea-sized amount of CoCl₂·6H₂O in 1–2 mL of distilled water in a test tube (pink). Keep it as a reference.
- In a fume cupboard, the teacher dissolves a pea-sized amount in 1–2 mL of concentrated HCl in a second tube (blue). Keep as a reference.
- In a third tube, dissolve a pea-sized amount in 1–2 mL of water, then add concentrated HCl dropwise (teacher) until the solution is purple (equilibrium mixture of both ions).
- Hold the purple tube with tongs in a 250 mL beaker of hot water (about 70°C) and record the colour after 2 minutes. Then place it in a beaker of ice water (about 0°C) and record again.
Diagram: three test tubes (references and equilibrium mixture), hot-water bath with thermometer, ice bath.
Risk assessment
- Concentrated HCl is very corrosive. The teacher dispenses it in a fume cupboard, because it burns skin and gives off irritating fumes.
- Cobalt(II) chloride is an irritant and a suspected carcinogen. Wear gloves and goggles and wash hands, because it can be absorbed through skin or inhaled as dust.
- Hot water can scald. Use tongs and a stable beaker, because spills burn.
Results and analysis: [Co(H₂O)₆]²⁺(aq) (pink) + 4Cl⁻(aq) ⇌ [CoCl₄]²⁻(aq) (blue) + 6H₂O(l). Heating gives blue, so the forward reaction is favoured and is endothermic (ΔH > 0). Cooling gives pink. Le Chatelier: increasing temperature favours the endothermic direction. By collision theory, more particles have energy ≥ activation energy at the higher temperature, and the endothermic reaction speeds up more.
Evaluation: A thermometer in each bath gives a controlled temperature. Compare against the references.
Experiment 5 – Effect of volume and pressure on a gaseous equilibrium (NO₂ ⇌ N₂O₄)
Syllabus: Investigate the effects of… volume and/or pressure on a system at equilibrium, e.g. interaction between NO₂ and N₂O₄.
Aim: To observe the effect of changing the volume of a gaseous equilibrium system.
Hypothesis: Reducing the volume will first darken the gas, then the colour will fade as the system shifts toward N₂O₄ (fewer gas moles).
Method (teacher demonstration)
- In a fume cupboard, hold a large sealed syringe containing NO₂/N₂O₄ and record the colour of the mixture.
- Quickly push in the plunger to reduce the volume (e.g. from 50 mL to 25 mL). Record the immediate colour, then again after about 30 seconds.
- Pull the plunger back to increase the volume and record the changes.
Risk assessment
- NO₂/N₂O₄ is toxic and corrosive to skin, eyes and lungs. Use a sealed syringe in a fume cupboard, so no gas escapes into the room.
Results and analysis: 2NO₂(g) (brown) ⇌ N₂O₄(g) (colourless). Compression first makes the gas darker (the same moles in a smaller volume, higher concentration). It then lightens as the system shifts to the side with fewer gas moles (N₂O₄). By collision theory, higher pressure increases collision frequency of both reactants and products, but the forward reaction (2 mol → 1 mol) is affected more. Expanding gives the opposite.
Experiment 6 – Keq of the iron(III) thiocyanate system
Syllabus: Conduct an investigation to determine Keq of a chemical equilibrium system, e.g. Keq of the iron(III) thiocyanate equilibrium.
Aim: To use colourimetry to determine Keq for Fe³⁺ + SCN⁻ ⇌ FeSCN²⁺.
Hypothesis: Keq will be consistent across mixtures of different starting concentrations at the same temperature.
Variables: Independent: initial concentrations of Fe³⁺ and SCN⁻. Dependent: absorbance (hence [FeSCN²⁺]). Controlled: wavelength (470 nm), temperature, acid concentration, cuvette path length.
Method
Part A – calibration standards (excess Fe³⁺ forces all SCN⁻ into FeSCN²⁺)
- Label six 100 mL volumetric flasks A–F. Pipette 25.00 mL of 0.200 mol L⁻¹ Fe(NO₃)₃ into each.
- Add 1.00, 2.00, 4.00, 6.00, 8.00 and 10.00 mL of 0.00200 mol L⁻¹ KSCN respectively, using a graduated pipette.
- Make each up to the 100.00 mL line with 0.5 mol L⁻¹ HNO₃ (dropper for the last few mL). Stopper and invert.
- Set the colourimeter to 470 nm and zero it with a cuvette ¾ full of distilled water.
- Rinse a cuvette and beaker with each solution in turn, fill the cuvette ¾, wipe the clear sides, and record the absorbance of A–F. Plot absorbance against [FeSCN²⁺] (= initial [SCN⁻] after dilution).
Part B – equilibrium mixtures (your teacher's table may differ)
6. In five labelled flasks mix 5.00 mL of 0.00200 mol L⁻¹ Fe(NO₃)₃ with 1.00, 2.00, 3.00, 4.00 and 5.00 mL of 0.00200 mol L⁻¹ KSCN, then make each up to 10.00 mL with 0.5 mol L⁻¹ HNO₃.
7. Measure the absorbance of each at 470 nm. Read [FeSCN²⁺]eq from the calibration graph.
Diagram: six 100 mL volumetric flasks with the reagent volumes marked; colourimeter with cuvette.
Risk assessment
- Nitric acid is corrosive. Wear goggles and gloves, because splashes burn skin and eyes.
- Iron(III) thiocyanate is harmful to aquatic life. Collect waste in the waste bottle so it doesn't enter the sink.
- Glassware may break. Keep it away from the bench edge and hold the pipette with its filler attached.
Calculation
- [Fe³⁺]initial and [SCN⁻]initial after mixing (C₁V₁ = C₂V₂).
- ICE table: [FeSCN²⁺]eq = x (from the graph), [Fe³⁺]eq = [Fe³⁺]initial − x, [SCN⁻]eq = [SCN⁻]initial − x.
- Keq = [FeSCN²⁺] ÷ ([Fe³⁺][SCN⁻]). Average across mixtures. Typical values are a few hundred (check your class value).
Evaluation: Use the same cuvette orientation. Keep the temperature constant, since Keq changes with temperature. Check linearity of the calibration curve (Beer–Lambert: A ∝ c). Air bubbles and fingerprints on the cuvette are common sources of error. Use fresh solutions.
Experiment 7 – Solubility rules and predicting precipitates
Syllabus: Conduct an investigation to determine solubility rules, and predict and analyse the composition of substances when two ionic solutions are mixed, e.g. KCl + AgNO₃, KI + Pb(NO₃)₂, Na₂SO₄ + Ba(NO₃)₂.
Aim: To compare the solubility of ionic compounds through precipitation reactions and construct solubility rules.
Hypothesis: All nitrates and group 1 salts will be soluble; the combinations Ag⁺/Cl⁻, Pb²⁺/I⁻ and Ba²⁺/SO₄²⁻ will precipitate.
Variables: Independent: the pair of ions mixed. Dependent: whether a precipitate forms and its colour. Controlled: concentration (0.1 mol L⁻¹), volume (one drop each), background.
Method
- Draw a grid on an overhead projector sheet with anions across the top (e.g. nitrate, chloride, sulfate, carbonate, acetate, hydroxide) and cations down the side (e.g. Na⁺, Ag⁺, Pb²⁺, NH₄⁺, Mg²⁺, Fe²⁺, Cu²⁺, Zn²⁺, Al³⁺, Ba²⁺, Ca²⁺, Fe³⁺).
- Place the sheet on a dark background (black paper or a dark bench).
- In each square put one drop of the cation solution and one drop of the anion solution (all 0.1 mol L⁻¹, lead nitrate 0.02 mol L⁻¹) from dropper bottles, one on top of the other.
- Record whether a precipitate forms and its colour. Wipe with paper towel and collect waste.
- Write net ionic equations for each precipitate. Compare your rules with a solubility data table.
Diagram: the grid with dropper bottles, showing two drops in one square.
Risk assessment
- Splashes irritate skin and eyes. Wear goggles and wash with soap and water if contact occurs.
- Lead, barium and silver salts are toxic and silver stains skin. Wear gloves, wipe up with paper towel and put it in the heavy-metal waste, not the sink, so toxic ions don't enter waterways.
Results and analysis
- KCl + AgNO₃ → white AgCl: Ag⁺(aq) + Cl⁻(aq) → AgCl(s).
- KI + Pb(NO₃)₂ → yellow PbI₂: Pb²⁺(aq) + 2I⁻(aq) → PbI₂(s).
- Na₂SO₄ + Ba(NO₃)₂ → white BaSO₄: Ba²⁺(aq) + SO₄²⁻(aq) → BaSO₄(s).
- Spectator ions (K⁺, Na⁺, NO₃⁻) stay in solution. Typical rules: all nitrates, group 1 salts and ammonium salts are soluble; most carbonates and hydroxides are insoluble except group 1.
Evaluation: Differences from published rules may come from slightly soluble salts (e.g. Ca(OH)₂, Ag₂SO₄), impure reagents or the tiny drop volumes. Repeating in test tubes with 1 mL gives a clearer observation.
MODULE 6 – ACID/BASE REACTIONS
Experiment 8 – Preparing and using indicators
Syllabus: Conduct an investigation to demonstrate the preparation and use of indicators as illustrators of the characteristics and properties of acids and bases and their reversible reactions.
Aim: To prepare natural indicators and test them on a range of substances.
Hypothesis: The natural indicators will give a range of different colours depending on the acidity or alkalinity of the substance.
Variables: Independent: the substance tested (and the indicator). Dependent: colour. Controlled: volume of substance (2 mL), number of indicator drops.
Method
- Red cabbage: shred two leaves into a 500 mL beaker and just cover with distilled water (about 200 mL). Heat on a hotplate and boil gently until the water is dark red-purple. Cool, then pour the liquid into a clean 100 mL beaker.
- Other plants (blueberries, petals, turmeric): grind in a mortar with 5–10 mL of warm water and strain through a filter into a beaker.
- Put 2 mL each of 0.1 mol L⁻¹ NaOH, 0.1 mol L⁻¹ HCl, vinegar, household ammonia, lemon juice, lemonade, bicarbonate of soda solution, washing powder solution, antacid solution and salt water into labelled test tubes in a rack.
- Add a few drops of the indicator to each and record the colour. Repeat for each indicator and compare with universal indicator.
- Reversibility: place 2 mL of HCl in a test tube with a few drops of indicator. Add NaOH dropwise until the colour stops changing. Then add HCl dropwise and watch the colour return.
Diagram: test-tube rack with labelled substances (2 mL) and indicator drops; the cabbage beaker on a hotplate.
Risk assessment
- NaOH is caustic and HCl corrosive. Wear goggles and protective clothing and wash spills with plenty of water, because they burn skin.
- Boiling water and a hotplate burn. Pour away from the body and use tongs, so scalds are avoided.
- Ammonia vapour irritates the lungs. Keep it stoppered and use a ventilated area.
Results and analysis: Red cabbage is red/pink in acids, purple when neutral, and blue/green/yellow in bases. Indicators change colour at different pH ranges, so some are better than others. The colour change reverses on adding acid or base, showing the reaction is reversible: HIn ⇌ H⁺ + In⁻. Universal indicator gives a more complete pH range than a single indicator.
Evaluation: Colour judgement is subjective; photograph against a white background. Home-made extracts vary in concentration, so use the same amount each time.
Experiment 9 – Enthalpy of neutralisation
Syllabus: Conduct a practical investigation to measure the enthalpy of neutralisation.
Aim: To determine the enthalpy of neutralisation of HCl with NaOH.
Hypothesis: The enthalpy change will be about −57 kJ per mole of water formed, for a strong acid and strong base.
Variables: Independent: the reactants (acid and base). Dependent: temperature change. Controlled: volumes, concentrations, same polystyrene cup, stirring.
Method
- Measure 50 mL of 2.0 mol L⁻¹ NaOH in a 100 mL measuring cylinder and pour it into a polystyrene cup standing in a 250 mL beaker. Record the temperature to ±0.1°C.
- Measure 50 mL of 2.0 mol L⁻¹ HCl in the cylinder and record its temperature. Average the two as the initial temperature.
- Pour the acid into the base, cover with a lid, stir gently with the thermometer and record the highest temperature reached.
- Repeat for reliability.
- (Optional Part A) Pour 100 mL of 1.0 mol L⁻¹ HCl into a cup. Weigh about 4.0 g of NaOH(s) and add it. Stir and record the highest temperature. Use the difference between A and B to explain the effect of the solid dissolving.
Diagram: polystyrene cup with lid, thermometer, 100 mL of solution and a surrounding beaker.
Risk assessment
- NaOH is caustic. Use a spatula and never your fingers, because it burns skin.
- HCl is corrosive. Wear goggles and protective clothing and pour carefully, to prevent splashes.
Calculation (example)
- q = mcΔT with m = 100 g, c = 4.18 J g⁻¹ K⁻¹. If ΔT = 13.7°C, q = 100 × 4.18 × 13.7 = 5.73 kJ.
- n(H₂O) = 0.100 mol (50 mL × 2.0 mol L⁻¹ = 0.100 mol).
- ΔH = −q ÷ n = −57 kJ mol⁻¹.
- NaOH + HCl → NaCl + H₂O; net ionic equation: H⁺ + OH⁻ → H₂O.
Evaluation: Heat is lost to the surroundings, so the measured value is lower in magnitude than the accepted value. Improve by using a lid and insulation, stirring consistently, and plotting temperature against time to extrapolate to the true maximum. The solution is assumed to have the same specific heat capacity and density as water.
Experiment 10 – Measuring pH of a range of acids and bases
Syllabus: Conduct a practical investigation to measure the pH of a range of acids and bases.
Aim: To measure and compare the pH of various substances using universal indicator and a pH meter.
Hypothesis: The pH meter will give more precise values than universal indicator.
Variables: Independent: the substance tested. Dependent: pH. Controlled: the volume of sample, calibration of the meter, rinsing between samples.
Method
- Calibrate the pH meter with buffer solutions (pH 4.01 and 7.00, and 10.01 if available).
- Place a few mL (enough to cover the probe) of each sample in a labelled test tube: vinegar, lemon juice, dishwasher detergent, shampoo, antacid solution, baking soda solution, vitamin C solution, bleach, soda water, and 1 and 0.0001 mol L⁻¹ HCl and NaOH. Dissolve solids in distilled water first.
- Measure the pH with the meter and record it. Rinse the probe with distilled water between each sample.
- Add one drop of universal indicator to each sample, record the colour and the pH from the chart.
- Test water samples (pool, creek) in the same way; filter or let sediment settle first.
Diagram: test-tube rack with labelled samples, a pH meter probe in a tube, universal indicator chart.
Risk assessment
- Household chemicals, NaOH and HCl can burn. Wear goggles and protective clothing, and tell the teacher about spills.
- Food products can be contaminated in the lab. Never taste or eat them.
Results and analysis: Acids are below 7 (vinegar about 2.5, lemon juice about 2), neutrals about 7, and bases above 7 (detergent, bleach about 12). pH = −log₁₀[H⁺]; 1 mol L⁻¹ HCl is pH 0 and 0.0001 mol L⁻¹ HCl is pH 4. The meter gives values to ±0.01 whereas universal indicator is only about ±0.5–1.
Evaluation: An uncalibrated meter gives systematic errors. Temperature affects pH. A dirty probe gives cross-contamination.
Experiment 11 – pH and the strength of acids and bases
Syllabus: Conduct an investigation to demonstrate the use of pH to indicate the differences between the strength of acids and bases.
Aim: To compare the pH of strong and weak acids and bases at the same and at different concentrations.
Hypothesis: At the same concentration, strong acids and bases will be more extreme in pH than weak ones.
Variables: Independent: the acid or base (and its concentration). Dependent: pH. Controlled: volume (25 mL), temperature, calibrated pH meter.
Method
- Same concentration: pour 25 mL of each 0.1 mol L⁻¹ solution (HCl, CH₃COOH, NaOH, NH₃) into separate clean 50 mL beakers. Measure each pH with a calibrated meter, rinsing the probe with distilled water between samples.
- Different concentrations: repeat with 25 mL of 0.01 mol L⁻¹ HCl and 0.01 mol L⁻¹ NaOH.
Risk assessment
- NaOH and HCl are corrosive. Wear goggles and protective clothing and rinse spills with plenty of water.
- Ammonia vapour irritates. Use in a ventilated area.
Results and analysis: 0.1 mol L⁻¹ HCl is about pH 1; 0.1 mol L⁻¹ CH₃COOH is about pH 2.9. HCl ionises fully (HCl + H₂O → H₃O⁺ + Cl⁻), acetic acid only partially (CH₃COOH + H₂O ⇌ H₃O⁺ + CH₃COO⁻). 0.1 mol L⁻¹ NaOH is about pH 13 and 0.1 mol L⁻¹ NH₃ is about pH 11. A tenfold dilution of a strong acid raises its pH by 1. Strength is how much it ionises; concentration is how much is dissolved.
Experiment 12 – Primary standard solution and titration
Syllabus: Conduct practical investigations to analyse the concentration of an unknown acid or base by titration.
Aim: To prepare a primary standard of sodium carbonate and use it to find the concentration of a hydrochloric acid solution.
Hypothesis: The concentration of HCl can be determined accurately from concordant titres.
Variables: Independent: volume of HCl added. Dependent: the end-point volume (titre). Controlled: volume of Na₂CO₃ (25.00 mL), indicator (2 drops), rinsing technique.
Method
Part A – primary standard (0.0500 mol L⁻¹ Na₂CO₃)
- Tare a clean, dry 150 mL beaker on a balance. Weigh about 1.4 g of anhydrous Na₂CO₃ to ±0.001 g and record the exact mass.
- Add about 80 mL of distilled water and stir until dissolved.
- Pour through a funnel into a 250.0 mL volumetric flask. Rinse the beaker three times with distilled water and add the rinsings, then rinse the funnel into the flask.
- Fill with distilled water until the bottom of the meniscus touches the line (dropper for the last few mL, eye level). Stopper and invert several times to mix.
- Calculate c = m ÷ (M × 0.2500), to 4 significant figures. Example: 1.400 g ÷ (105.99 × 0.2500) = 0.05284 mol L⁻¹.
Part B – titration
6. Rinse the burette with a small volume of the HCl and fill it, removing air from the tip. Record the initial reading to ±0.05 mL.
7. Rinse the 25.00 mL pipette with the Na₂CO₃ solution. Pipette 25.00 mL into a 250 mL conical flask that has been rinsed with distilled water only. Add 2 drops of methyl orange.
8. Place the flask on a white tile under the burette. Titrate with swirling to the first permanent orange-red, adding dropwise near the end. Record the final reading.
9. Repeat until you have titres agreeing within 0.10 mL (concordant). Average the concordant titres.
Diagram: burette with HCl clamped over a conical flask on a white tile with 25.00 mL Na₂CO₃ and 2 drops of methyl orange; separate sketch of the volumetric flask with the meniscus on the line.
Risk assessment
- Solid Na₂CO₃ irritates the skin and eyes. Wear goggles and wash hands afterwards.
- Glassware can break and cut. Keep it from the edge and leave the pipette filler on the pipette so it can't roll off.
- Dilute acid may splash. Fill the burette below eye level using a funnel, so acid does not reach the face.
Calculation: Na₂CO₃ + 2HCl → 2NaCl + H₂O + CO₂, so n(HCl) = 2 × n(Na₂CO₃). c(HCl) = n(HCl) ÷ V(titre in L).
Why it matters (common exam questions)
- Rinse the burette with the solution it will hold (water would dilute it), the pipette with its own solution, and the conical flask with water only (rinsing with sample would add extra moles).
- Anhydrous Na₂CO₃ is a primary standard because it is pure, stable and has a known formula. The hydrate's water content is variable.
- Methyl orange suits a strong acid with a weak base because the equivalence point is acidic. Equivalence point is the exact stoichiometric point; end point is the observed colour change. They should be close.
- Parallax error: read the burette with the eye level with the meniscus.
Evaluation: Concordant titres show reliability. Use a white tile to judge the colour change. A burette reading uncertainty is ±0.05 mL. Overshooting the end point is the most common random error.
Experiment 13 – Chemical analysis of a household substance
Syllabus: Conduct a chemical analysis of a common household substance for its acidity or basicity, e.g. soft drink, wine, juice, medicine.
Aim: To determine the acid content of orange juice by titration with NaOH, and the aspirin content of a tablet by back titration.
Part A – orange juice
Hypothesis: The acidity of the juice (as citric acid) can be determined from the pH–volume curve.
Method
- Weigh a clean 250 mL beaker, add about 20 mL of juice and reweigh (mass of juice).
- Add about 50 mL of distilled water so the pH electrode is covered.
- Fill a burette with about 0.1 mol L⁻¹ standardised NaOH. Place the calibrated pH meter in the beaker and record the initial pH.
- Add NaOH in 1 mL steps, recording pH after each, until the pH is steady in the basic region.
- Repeat with smaller steps (0.2 mL) near the steep rise.
- Plot pH against volume of NaOH. Find the equivalence volume from the middle of the steep rise.
Why a pH meter: the orange colour hides indicator colour changes.
Calculation: Citric acid is triprotic: H₃C₆H₅O₇ + 3NaOH → Na₃C₆H₅O₇ + 3H₂O. n(NaOH) = c × V; n(acid) = n(NaOH) ÷ 3; mass = n × 192.12 g mol⁻¹; % w/w = mass ÷ mass of juice × 100.
Part B – aspirin by back titration
Method
- Blank: pipette 5.00 mL of ethanol and 25.00 mL of 0.5 mol L⁻¹ NaOH into a 250 mL conical flask. Add 1–2 drops of phenolphthalein. Titrate with 0.5 mol L⁻¹ HCl until the pink just disappears. Repeat until concordant.
- Sample: crush an aspirin tablet in a mortar and weigh about 0.5 g into a flask. Add 5.00 mL of ethanol and 25.00 mL of 0.5 mol L⁻¹ NaOH. Stopper and leave for 1 hour.
- Add indicator and titrate the excess NaOH with 0.5 mol L⁻¹ HCl to the colourless end point.
- n(NaOH reacted with aspirin) = n(NaOH in blank) − n(NaOH in sample). Aspirin reacts with 2 NaOH (acid plus ester hydrolysis), so n(aspirin) = ½ × that.
Why back titration: the weak acid with strong base gives a poor end point; a strong acid with strong base gives a sharp one.
Risk assessment
- NaOH splashes irritate and burn. Wear goggles and wash hands.
- Ethanol is flammable. Keep it away from flames and work in a ventilated area, because vapour ignites.
- Glassware can break. Keep it away from the bench edge.
Evaluation: Compare the result with the label value and calculate percentage error. Likely errors: incomplete hydrolysis, loss of sample, other acids in the juice (assumed all citric acid).
Experiment 14 – Preparing a buffer and demonstrating its properties
Syllabus: Conduct a practical investigation to prepare a buffer and demonstrate its properties.
Aim: To compare how a buffered and an unbuffered solution respond to added acid and base.
Hypothesis: The buffered solution will resist pH change when acid or base is added; the unbuffered solution will not.
Variables: Independent: buffered or unbuffered. Dependent: pH (universal indicator colour). Controlled: starting pH, volume (20 mL), number of drops added, concentration of acid/base (0.1 mol L⁻¹).
Method
- Measure 10 mL of 0.2 mol L⁻¹ CH₃COOH and 40 mL of 0.2 mol L⁻¹ CH₃COONa into a clean beaker and stir (the buffer).
- Pour 20 mL of the buffer into each of two 150 mL beakers. Add 5 drops of universal indicator to each and record the colour and pH.
- In a fourth beaker add 50 mL of distilled water and 10 drops of universal indicator. Add 0.1 mol L⁻¹ HCl dropwise until the colour matches the buffer. Pour 20 mL into each of two beakers (unbuffered).
- To one buffered and one unbuffered beaker add 0.1 mol L⁻¹ HCl one drop at a time up to 40 drops, stirring each time. Record the colour and pH.
- Repeat with 0.1 mol L⁻¹ NaOH in the other pair.
Diagram: four beakers (two buffered, two unbuffered) labelled with the added acid or base and the 20 mL volumes.
Risk assessment
- HCl and NaOH are corrosive. Wear gloves, goggles and an apron, because they burn skin and eyes.
- Spills on benches can cause burns. Wipe immediately.
Results and analysis: The buffered solutions change colour only slightly after 40 drops; the unbuffered ones change quickly. CH₃COOH ⇌ H⁺ + CH₃COO⁻. Added H⁺ reacts with CH₃COO⁻ (shift left); added OH⁻ reacts with H⁺, which CH₃COOH replaces (shift right). A buffer has a weak acid and its conjugate base in comparable amounts.
Evaluation: Use a pH meter for accurate values. Buffer capacity is limited: continued addition will eventually overwhelm it.
MODULE 7 – ORGANIC CHEMISTRY
Experiment 15 – Properties within a homologous series (solubility of alcohols)
Syllabus: Conduct an investigation to compare the properties of organic chemical compounds within a homologous series, and explain the differences in terms of bonding.
Aim: To investigate how the solubility of alcohols in water changes with chain length.
Hypothesis: Solubility decreases as the carbon chain gets longer, because the non-polar hydrocarbon part outweighs the polar –OH group.
Variables: Independent: the alcohol (number of carbons). Dependent: whether it mixes with water (layers). Controlled: volume of water (3 mL), volume of alcohol (2 mL), temperature, food-colouring amount.
Method
- Label six small test tubes 1–6 for methanol, ethanol, 1-propanol, 1-butanol, 1-pentanol and 1-hexanol.
- Add 3 mL of deionised water and 2 drops of food colouring to each tube. Food colouring dissolves in water but not in non-polar liquids, so it shows the water layer.
- Add 2 mL of each alcohol to its tube and observe or photograph any layers.
- Add a further 2 mL of each alcohol and note any change.
Diagram: rack with six tubes labelled by alcohol, each showing 3 mL of coloured water and 2 mL of alcohol, with any layers drawn in.
Risk assessment
- Alcohol vapour is harmful and flammable. Use small volumes in a fume cupboard or ventilated area, keep containers closed and away from flames, because vapours ignite and irritate the lungs.
- Splashes irritate skin and eyes. Wear gloves, goggles and a lab coat.
Results and analysis: Methanol, ethanol and propanol mix completely (one layer). Butanol is partly soluble, and pentanol and hexanol form two layers. The –OH forms hydrogen bonds with water, but as the non-polar chain lengthens, dispersion forces dominate and the alcohol is less soluble.
Evaluation: Judge "mixing" the same way each time and photograph each tube. Shake the same number of times.
Experiment 16 – Comparing alkanes and alkenes
Syllabus: Investigate the reactions of unsaturated and saturated hydrocarbons (alkanes and alkenes) and compare their properties.
Aim: To compare the reactivity of an alkane and an alkene with bromine water and acidified potassium permanganate.
Hypothesis: The alkene will decolourise bromine water and permanganate quickly; the alkanes will not react under the same conditions.
Variables: Independent: the hydrocarbon (hexane, cyclohexane, cyclohexene). Dependent: colour change. Controlled: volumes (1 mL each), time observed (5 minutes), temperature, no UV light.
Method
- Permanganate: label three test tubes for hexane, cyclohexane and cyclohexene and add 1 mL of each hydrocarbon. In a clean tube mix 4 mL of 0.01 mol L⁻¹ KMnO₄ with 2 mL of 2.0 mol L⁻¹ H₂SO₄. Add 1 mL of this to each hydrocarbon, shake gently and watch for 5 minutes.
- Bromine water: in clean labelled tubes put 1 mL of each hydrocarbon, add 1 mL of bromine water, shake gently and watch for 5 minutes. If the colour changes, add a further 1 mL.
- Pour all waste into the labelled chemical waste jar and rinse tubes with deionised water. Do not use the sink.
Diagram: rack with three tubes each showing 1 mL of hydrocarbon plus 1 mL of reagent, colour before and after.
Risk assessment
- Cyclohexane and cyclohexene are toxic and highly flammable. Use a fume cupboard with no flame sources, because vapours ignite and irritate the lungs.
- Bromine water is poisonous and corrosive. Wear gloves, goggles and a lab coat and use a fume cupboard, to avoid skin contact and inhalation.
- Sulfuric acid is corrosive. Wear gloves and a lab coat, because splashes burn.
Results and analysis: Alkene + Br₂ → dibromoalkane (addition): orange bromine water becomes colourless. The alkene also decolourises acidified permanganate (purple to colourless/brown) because C=C is oxidised. Alkanes show no change in the dark because their C–C and C–H single bonds are strong and non-polar; alkanes only react with halogens by substitution in UV light. The double bond contains a weaker pi bond that is attacked.
Evaluation: Cyclohexane and cyclohexene are used because they are liquids. A negative result does not prove no reaction, only none at that rate.
Experiment 17 – Enthalpy of combustion of alcohols
Syllabus: Conduct a practical investigation to measure and reliably compare the enthalpy of combustion for a range of alcohols.
Aim: To measure the enthalpy of combustion of several alcohols and compare it with theoretical values.
Hypothesis: The enthalpy of combustion per mole will increase with chain length.
Variables: Independent: the alcohol (molar mass/chain length). Dependent: temperature rise of the water (and mass of fuel burnt). Controlled: 100 mL of water, same beaker, distance from flame to beaker (about 5 cm), same temperature rise, draught shields.
Method
- Measure 100 mL of water in a measuring cylinder into a 250 mL beaker and clamp it about 5 cm above a spirit burner. Record the initial temperature to ±0.5°C.
- Weigh the spirit burner containing methanol, with its cap, on a balance (±0.01 g).
- Light the burner and stir the water gently with the thermometer. When the temperature has risen by 20°C, extinguish with the cap.
- Reweigh the burner and calculate the mass of alcohol burnt.
- Repeat with ethanol, 1-propanol, 1-butanol and 1-pentanol using fresh water each time, and with repeats for reliability.
Diagram: beaker on a clamp and retort stand with 100 mL water, thermometer, spirit burner of alcohol, 5 cm gap marked, draught shield.
Risk assessment
- Alcohols are flammable liquids. Use spirit burners with caps so the fuel is separate from the flame, and keep the bench clear.
- Hot glassware burns. Use beaker gloves and allow equipment to cool, because direct contact scalds.
- Methanol is toxic. Don't inhale the vapour and wash hands afterwards.
Calculation (example, ethanol): q = mcΔT = 100 × 4.18 × 20 = 8.36 kJ. If 0.45 g burnt, n = 0.45 ÷ 46.07 = 0.00977 mol. ΔH = −q ÷ n ≈ −856 kJ mol⁻¹ (accepted about −1367 kJ mol⁻¹).
Results and analysis: Plot ΔH (y) against molar mass (x). ΔH becomes more negative with chain length because more C–H/C–C bonds are broken and more CO₂ and H₂O are formed per mole.
Evaluation: Values are often far lower than the accepted values because heat is lost to the air and beaker, combustion is incomplete (soot), and the wick or fuel evaporates. Improve with a draught shield and a copper calorimeter, with the flame closer to the container, and by stirring constantly.
Experiment 18 – Reactivity of primary, secondary and tertiary alcohols (oxidation)
Syllabus: Conduct a laboratory experiment to demonstrate the reactivity of primary, secondary and tertiary alcohols; investigate the oxidation of primary and secondary alcohols.
Aim: To compare the oxidation of primary, secondary and tertiary alcohols.
Hypothesis: Primary and secondary alcohols will be oxidised (colour change); tertiary alcohols will not.
Variables: Independent: the alcohol (primary, secondary, tertiary) and the oxidant. Dependent: colour change. Controlled: volumes (2 mL alcohol), water-bath temperature, time.
Method
- Fill a 250 mL beaker with hot water from a kettle (about 70°C) as a water bath.
- Part A (permanganate): put 2 mL each of ethanol, 1-butanol, 2-butanol and 2-methyl-2-propanol into labelled tubes. Mix 4 mL of 0.01 mol L⁻¹ KMnO₄ with 1 mL of 6 mol L⁻¹ H₂SO₄ in a separate tube. Add 4–5 drops to each alcohol and warm in the bath for 1–2 minutes.
- Part B (dichromate): repeat with new alcohol samples using 4 mL of 0.1 mol L⁻¹ Na₂Cr₂O₇ mixed with 2 mL of 6 mol L⁻¹ H₂SO₄. Add 1 mL to each alcohol and warm for 5 minutes.
- Record colour changes and dispose of waste in the waste container.
Diagram: four tubes in a hot-water bath with thermometer, labelled with the alcohol and 2 mL.
Risk assessment
- Dichromate is toxic and a carcinogen. Wear gloves, goggles and a lab coat and use a fume cupboard, to avoid skin contact and inhalation.
- Sulfuric acid is corrosive. The teacher dispenses it; wear PPE.
- Alcohols are flammable. Keep away from flames and use a hot-water bath rather than a Bunsen.
Results and analysis
- Primary: ethanol → ethanal → ethanoic acid. Orange dichromate turns green (Cr₂O₇²⁻ → Cr³⁺); purple permanganate fades.
- Secondary: 2-butanol → butanone (a ketone). Same colour change.
- Tertiary: no reaction, because there is no hydrogen on the carbon bearing the –OH, so the colour stays orange/purple.
Evaluation: The test can't distinguish primary from secondary (both react). Adding Na₂CO₃ or testing for an acid product can tell them apart. Heat for the same time for fairness.
Experiment 19 – Production of alcohol by fermentation
Syllabus: Investigate the production of alcohols, including fermentation.
Aim: To set up a fermentation mixture and measure the rate of reaction.
Hypothesis: The mass of the mixture will decrease over time as CO₂ escapes, and ethanol will be produced.
Variables: Independent: time. Dependent: mass of the apparatus. Controlled: 5 g yeast, 10 g glucose, 40 mL warm water, temperature 25–30°C.
Method
- Place 5 g of dried yeast in a 250 mL conical flask. Add 10 g of glucose and 40 mL of warm water (30–40°C) and swirl.
- Fit a one-hole stopper with a plastic-tube airlock part-filled with water, so gas escapes but air doesn't enter.
- Weigh the whole set-up and record the mass. Store at 25–30°C (an incubator or a sunny window).
- Weigh again at regular intervals for 2–3 days, recording the hours elapsed.
- In one session bubble the gas through limewater in a test tube.
- At the end, take about 5 mL of the mixture and add 1 mL of acidified dichromate (as in Experiment 18) in a hot-water bath.
Diagram: conical flask with yeast/glucose/water, one-hole stopper with tube leading to a water airlock, labelled quantities and temperature.
Risk assessment
- CO₂ pressure can build up in a sealed flask. Use an airlock so gas escapes, because pressure can burst glassware.
- Ethanol is flammable. Keep clear of flames.
- Dichromate and sulfuric acid are corrosive and toxic. Use PPE and a fume cupboard.
Results and analysis: C₆H₁₂O₆ → 2C₂H₅OH + 2CO₂. Mass is lost as CO₂ escapes, so a graph of mass lost against time shows the rate (the gradient). Limewater turns milky: Ca(OH)₂ + CO₂ → CaCO₃ + H₂O. Dichromate turning orange to green shows ethanol is present.
Evaluation: Evaporation of water and ethanol also lowers the mass. Yeast dies at high ethanol concentration or temperature, so the rate eventually drops.
Experiment 20 – Production of an ester
Syllabus: Investigate the production, in a school laboratory, of simple esters.
Aim: To make and purify an ester (pentyl ethanoate).
Hypothesis: Refluxing a carboxylic acid and an alcohol with an acid catalyst will produce a fruity-smelling ester that can be purified by washing.
Variables: Independent: the alcohol and carboxylic acid used. Dependent: ester formed (smell, volume). Controlled: reflux time (30 minutes), amounts, catalyst.
Method
- Into a round-bottom flask add 10 mL of 1-pentanol, 12 mL of glacial ethanoic acid, 1 mL of concentrated H₂SO₄ and a few boiling chips. Clamp the flask securely.
- Fit a condenser vertically. Connect water in at the bottom and out at the top. Do not stopper the top.
- Heat with a heating mantle at a constant rate for about 30 minutes, making sure vapours do not escape from the top of the condenser.
- Cool, then decant (without the chips) into a separating funnel containing 15 mL of water. Stopper, shake, vent, let the layers separate and drain off the lower aqueous layer.
- Add about 15 mL of 1.0 mol L⁻¹ sodium carbonate in portions, venting the CO₂. Shake, vent again, and drain the aqueous layer.
- Add 10 mL of deionised water, shake, separate and discard the aqueous layer.
- If time permits, distil the ester, collecting the liquid near its boiling point (149°C for pentyl ethanoate).
- Record the smell, colour and volume.
Diagram: reflux apparatus with round-bottom flask (reagent volumes labelled), boiling chips, heating mantle, vertical condenser with water in and out, clamps; separate sketch of a separating funnel with the two layers.
Risk assessment
- Organic liquids are flammable. Use a heating mantle instead of a Bunsen burner and keep reagents away from flames, because vapours ignite.
- Vapours are toxic and irritating. Work in a fume cupboard and keep containers stoppered, to avoid inhalation.
- Concentrated H₂SO₄ is corrosive. The teacher dispenses it and PPE is worn, because it causes severe burns.
- Gas can build up. Leave the condenser top open and vent the funnel after shaking, because trapped pressure can eject the stopper.
Results and analysis: CH₃COOH + C₅H₁₁OH ⇌ CH₃COOC₅H₁₁ + H₂O (esterification, condensation). The ester has a banana-like smell.
- Why reflux: it lets you heat a volatile mixture for a long time without losing reactants or products (vapour condenses and returns).
- Why concentrated H₂SO₄: catalyst, and it absorbs water, shifting the equilibrium toward the ester.
- Why excess acid: shifts the equilibrium to the right (Le Chatelier).
- Why Na₂CO₃: neutralises leftover acid (2CH₃COOH + Na₂CO₃ → 2CH₃COONa + H₂O + CO₂), making it water-soluble so it can be removed.
- Why the funnel: the ester is non-polar and less dense than water, so it separates as the upper layer.
Evaluation: Yield is low because the reaction is reversible and some product is lost in transfers and washing. Impurities include unreacted alcohol. Distillation improves purity.
Experiment 21 – Organic acids and bases
Syllabus: Investigate the differences between an organic acid and an organic base.
Aim: To compare some properties of organic acids and bases.
Hypothesis: Carboxylic acids will be acidic (pH < 7, fizz with carbonate) and amines basic (pH > 7); organic acids will be weaker than HCl at the same concentration.
Variables: Independent: the substance (acid or base). Dependent: pH and reaction observations. Controlled: concentration (0.10 mol L⁻¹), volume (2 mL).
Method
- Measure the pH of 0.10 mol L⁻¹ solutions of ethanoic acid, methanoic acid, citric acid and HCl with a calibrated pH probe.
- Place 2 mL of each acid in separate test tubes and add 2 mL of 0.10 mol L⁻¹ sodium carbonate. Record observations.
- To 2 mL of each acid add 2 mL of 0.10 mol L⁻¹ NaOH and 2–3 drops of universal indicator, and record the colour.
- Repeat each test with 2 mL of 0.10 mol L⁻¹ of an organic base (e.g. diethylamine).
Diagram: rack with labelled tubes (acid or base, 2 mL) and the reagent added to each.
Risk assessment
- Organic compounds can release toxic, irritating vapours. Keep containers stoppered and work in a fume cupboard or ventilated area.
- Acids and bases are corrosive. Wear PPE and wash hands afterwards.
Results and analysis: Organic acids give CO₂ with carbonate (2RCOOH + Na₂CO₃ → 2RCOONa + H₂O + CO₂). They have higher pH than HCl because they ionise only partially (weak acids). Amines accept H⁺ (RNH₂ + H₂O ⇌ RNH₃⁺ + OH⁻), giving pH > 7 and neutralising acids. Methanoic acid is stronger than ethanoic because the longer alkyl chain donates electrons and weakens the acid.
Experiment 22 – Soaps and detergents
Syllabus: Investigate the structure and action of soaps and detergents.
Aim: To make soap and compare the action of soaps and detergents.
Hypothesis: The soap I make will lather and have a basic pH. Soaps will form scum in hard water, but synthetic detergents will not.
Variables: Independent: type of cleaning agent; type of water (deionised or hard). Dependent: lather height and presence of scum. Controlled: amount of each sample, 5 mL of water, number of shakes.
Method
Part A – making soap (saponification)
- Warm about 75 mL of water in a 250 mL beaker on a hotplate (water bath).
- Pour 6 mL of vegetable oil into a 150 mL beaker.
- Weigh 2.5 g of NaOH in a 50 mL beaker and dissolve it in 20 mL of 50% ethanol/water (the ethanol helps the oil and NaOH mix). Add this slowly to the oil with continuous stirring.
- Place the beaker in the water bath and heat gently with frequent stirring for about 30 minutes, until thick and creamy. Do not overheat or it may spit.
- Add 25 mL of water and stir. Pour the mixture into 150 mL of saturated NaCl solution in a 250 mL beaker (salting out) and stir. Let it cool.
- Skim off the soap, rinse twice with deionised water, and dry on paper towel.
Part B – testing
7. Put a small equal amount of your soap, bath soap, liquid soap and a detergent in separate test tubes. Add 5 mL of deionised water, stopper and shake. Record lather height. Test pH with universal indicator.
8. Hard water: repeat with 5 mL of 0.1 mol L⁻¹ CaCl₂ instead of water and record lather and scum.
9. Emulsifier: in two tubes place 5 mL of vegetable oil and 5 mL of water. Add 5 drops of detergent to one. Stopper and shake both and compare.
Diagram: water bath on hotplate with reaction beaker (oil, NaOH solution), stirring rod and thermometer; test-tube rack for Part B with 5 mL labels.
Risk assessment
- NaOH is corrosive. Wear gloves and goggles and wash hands afterwards, because it burns skin.
- Ethanol is flammable. Keep it away from flames and use a hotplate.
- The hot mixture can spit. Stir constantly and don't overheat, so hot liquid doesn't splash.
- Detergents irritate skin. Wear PPE.
Results and analysis
- Triglyceride + 3NaOH → glycerol + 3 sodium carboxylate (soap). It is basic (pH ~9–10) because of excess alkali and hydrolysis of the soap.
- Soap in hard water: 2RCOO⁻ + Ca²⁺ → (RCOO)₂Ca(s). This scum reduces cleaning. Synthetic detergents (e.g. sulfonates) stay soluble with Ca²⁺ and Mg²⁺.
- Structure and action: soap ions have a non-polar hydrocarbon tail (dissolves in oil) and a polar, charged head (dissolves in water). They surround grease in micelles, which lets oil be washed away (emulsifier). Detergents lower the surface tension of water.
Evaluation: Judge lather height with a ruler. Impure home-made soap still contains NaOH and glycerol. Repeat for reliability.
MODULE 8 – APPLYING CHEMICAL IDEAS
Experiment 23 – Flame tests
Syllabus: Conduct qualitative investigations using flame tests… to test for the presence of ions in aqueous solution.
Aim: To identify metal cations by flame colour.
Hypothesis: Each metal ion will give a characteristic flame colour, so compounds with the same cation will give the same colour.
Variables: Independent: the metal compound. Dependent: flame colour. Controlled: the same wire cleaning, the same blue flame, same amount of sample.
Method
- Half-fill one 150 mL beaker with distilled water and another with 1 mol L⁻¹ HCl, deep enough to submerge the nichrome loop.
- Clean the loop by dipping it in water then in HCl, then holding it in the blue Bunsen flame until no colour shows.
- Touch the loop to the sample (e.g. copper(II) sulfate) and place it in the edge of the blue flame. Record the colour.
- Clean the loop again between samples. Test: CuSO₄, CuCl₂, Ca(NO₃)₂, CaCl₂, BaCl₂, Ba(NO₃)₂, Pb(NO₃)₂, an iron salt.
Diagram: Bunsen burner with the blue flame, nichrome loop with sample, heatproof mat, beakers of water and HCl.
Risk assessment
- The Bunsen flame is hot. Switch it to a yellow safety flame when idle, tie hair back and use a heatproof mat, because burns and fires can occur.
- Lead and barium compounds are toxic. Wear goggles and gloves and wash hands, so they are not absorbed or ingested.
- 1 mol L⁻¹ HCl may irritate. Wear goggles.
Results and analysis: Typical colours are Cu blue-green, Ca orange-red, Ba pale green, Pb pale blue-white, Fe gold sparks (check your table). The flame colour depends on the metal ion, not the anion. Heat excites electrons to higher energy levels, and when they fall back they emit light of specific wavelengths.
Evaluation: Sodium contamination (yellow) can mask other colours. Judging colour is subjective, so a spectroscope gives better evidence. Not all ions give a distinct colour (e.g. Mg²⁺).
Experiment 24 – Identifying cations in solution
Syllabus: Conduct qualitative investigations using precipitation and complexation reactions to test for the cations Ba²⁺, Ca²⁺, Mg²⁺, Pb²⁺, Ag⁺, Cu²⁺, Fe²⁺, Fe³⁺.
Aim: To identify cations by their reactions with a series of reagents, then identify an unknown.
Hypothesis: Each cation gives a unique pattern of precipitates with NaOH, ammonia, sulfate and other reagents.
Variables: Independent: the reagent added. Dependent: precipitate formation and colour. Controlled: 10 drops of each 0.1 mol L⁻¹ cation, 2 drops of reagent.
Method
- Add 10 drops of each 0.1 mol L⁻¹ cation solution to separate clean test tubes (one tube per cation).
- Add 2 drops of 0.1 mol L⁻¹ NaOH to each. Record "ppt" and its colour, or "NP" for no precipitate. Where a precipitate formed, add excess NaOH and record.
- Clean the tubes and repeat with ammonia solution (including excess), then with sulfate solution.
- Additional tests: add 2 drops of SCN⁻ to Fe²⁺ and Fe³⁺; add 2 drops of acidified KMnO₄ to Fe²⁺ and Fe³⁺; add 2 drops of F⁻ to Ba²⁺ and Ca²⁺; add 2 drops of Cl⁻ to Ag⁺ and Pb²⁺ then 5 drops of ammonia; add 2 drops of I⁻ to Pb²⁺.
- Obtain unknown samples (each contains one cation) and apply the same tests to identify them.
Diagram: rack of eight tubes, each with a labelled cation and the reagent added; a flow chart for the unknown.
Risk assessment
- NaOH and H₂SO₄ are corrosive. Wear goggles and protective clothing, and wash with water for 10–15 minutes if contact occurs, because they burn skin.
- Silver, barium, copper and lead salts are poisonous and silver stains skin. Avoid contact and dispose of waste as directed (heavy-metal waste), to protect people and waterways.
- Concentrated ammonia is irritating. Use in a fume cupboard.
Key results
| Cation |
NaOH |
Other tests |
| Ag⁺ |
brown ppt, insoluble in excess |
Cl⁻ gives white AgCl, dissolves in NH₃ |
| Mg²⁺ |
white ppt |
no ppt with SO₄²⁻ |
| Pb²⁺ |
white ppt, dissolves in excess |
I⁻ gives yellow PbI₂; SO₄²⁻ gives white ppt |
| Cu²⁺ |
blue ppt |
solution blue; excess NH₃ gives deep-blue complex |
| Fe²⁺ |
green ppt |
decolourises acidified MnO₄⁻ |
| Fe³⁺ |
red-brown ppt |
SCN⁻ gives blood-red FeSCN²⁺ |
| Ba²⁺ |
no or slight ppt |
SO₄²⁻ gives white BaSO₄ |
| Ca²⁺ |
slight white ppt |
F⁻ gives white CaF₂ |
Evaluation: Contaminated tubes and impure reagents produce false results. Use confirmation tests, because some precipitates look similar (e.g. Mg²⁺ and Pb²⁺ with NaOH).
Experiment 25 – Identifying anions in solution
Syllabus: Conduct qualitative investigations to test for the anions Cl⁻, Br⁻, I⁻, OH⁻, CH₃COO⁻, CO₃²⁻, SO₄²⁻, PO₄³⁻.
Aim: To devise and carry out tests to identify these anions and an unknown sample.
Hypothesis: Each anion can be identified by a distinctive reaction or sequence of tests.
Variables: Independent: the reagent. Dependent: precipitate, gas, colour or smell. Controlled: 1–2 mL of 0.1 mol L⁻¹ anion solution, equal reagent volumes, anion solutions free of unwanted cations.
Method
- Hydroxide: test 2 mL of sample with red litmus (blue) or universal indicator (alkaline).
- Carbonate: add 1 mL of dilute HCl to 2 mL of sample. Fizzing that turns limewater milky shows CO₃²⁻.
- Sulfate: add 1 mL of 0.1 mol L⁻¹ Ba(NO₃)₂, then a few drops of dilute HNO₃. A white precipitate that persists is BaSO₄.
- Halides: acidify 2 mL of sample with 2–3 drops of dilute HNO₃ (to remove CO₃²⁻/OH⁻), then add 1 mL of 0.1 mol L⁻¹ AgNO₃. White = Cl⁻, cream = Br⁻, yellow = I⁻. Confirm with dilute ammonia: AgCl dissolves readily.
- Phosphate: add AgNO₃ to a fresh sample: yellow Ag₃PO₄ that dissolves in dilute HNO₃ (or use barium nitrate and test solubility in acid).
- Acetate: no precipitate with the above reagents. Teacher confirms by warming with ethanol and a drop of concentrated H₂SO₄ in a fume cupboard for a fruity ester smell.
- Obtain an unknown and follow the sequence, using confirmation tests.
Diagram: flow chart of the test sequence plus a rack of tubes showing reagent volumes.
Risk assessment
- Concentrated acids and ammonia are dangerous. Use them in a fume cupboard, to avoid inhaling fumes and burns.
- Silver and barium salts are toxic. Wear PPE and dispose of waste as directed.
- Glass can break. Handle with care.
Evaluation: Results can be ambiguous when similar precipitates form (e.g. Ag₂CO₃ white, AgCl white), which is why you acidify first and use confirmation tests. Carbonate and hydroxide solutions are both basic, so test with acid as well.
Experiment 26 – Gravimetric analysis (sulfate in lawn fertiliser)
Syllabus: Conduct investigations and/or process data involving gravimetric analysis.
Aim: To determine the percentage of sulfate in a lawn fertiliser.
Hypothesis: The percentage of sulfate will be close to the value stated on the packet.
Variables: Independent: mass of fertiliser (about 1.00 g). Dependent: mass of BaSO₄. Controlled: temperature, amount of BaCl₂ added until precipitation is complete, drying to constant mass.
Method
- Weigh about 1.00 g of fertiliser accurately into a 250 mL beaker. Add about 50 mL of deionised water and 1 mL of dilute HCl, and stir to dissolve.
- Heat to near boiling. Add 0.1 mol L⁻¹ BaCl₂ dropwise until no more white precipitate forms.
- Keep the mixture gently heated (not boiling) for about an hour so crystals grow and filter easily.
- Weigh a filter paper beforehand. Filter through it using a funnel, rinsing the beaker into the funnel. Wash the precipitate with hot deionised water.
- Dry the filter paper and precipitate in an oven at about 100°C. Cool in a desiccator and weigh. Repeat the drying until the mass is constant.
Diagram: beaker on a hotplate with fertiliser solution and BaCl₂ added dropwise from a burette; filter funnel and flask; oven.
Risk assessment
- Barium salts are toxic. Wear gloves, goggles and wash hands, and dispose of the precipitate in the heavy-metal waste.
- HCl is corrosive. Wear goggles.
- Hot liquids and oven burn. Use tongs and a heatproof mat.
Calculation: Ba²⁺ + SO₄²⁻ → BaSO₄. Mass SO₄²⁻ = mass BaSO₄ × (96.06 ÷ 233.4). % sulfate = mass of SO₄²⁻ ÷ mass of fertiliser × 100.
Evaluation: Sources of error include solubility of BaSO₄ (low result), co-precipitation of impurities (high result), fine particles passing through the filter, loss of precipitate in transfer and incomplete drying. Heating the precipitate slowly (digestion) and washing improve purity.
Experiment 27 – Precipitation titration (Volhard's method for iodide)
Syllabus: Conduct investigations and/or process data involving precipitation titrations.
Aim: To determine the concentration of iodide ions in a solution.
Hypothesis: A back titration with thiocyanate will give an accurate iodide concentration.
Variables: Independent: volume of NaSCN added. Dependent: end-point volume (permanent red). Controlled: 10.00 mL sample, 10.00 mL AgNO₃, indicator and acid volumes.
Method
- Pipette 10.00 mL of the 0.1 mol L⁻¹ NaI sample into a 250 mL conical flask.
- Pipette 10.00 mL of 0.1 mol L⁻¹ AgNO₃ (excess) into the flask. Add 5 mL of 1.0 mol L⁻¹ HNO₃ and 1 mL of saturated ferric ammonium sulfate. Prepare three flasks.
- Fill a burette with 0.1 mol L⁻¹ NaSCN and record the initial reading.
- Titrate the excess Ag⁺ until a permanent blood-red colour (FeSCN²⁺) appears. Record the final reading.
Diagram: burette of NaSCN over a conical flask containing AgI precipitate, Ag⁺ excess and indicator.
Risk assessment
- Nitric acid is corrosive. Wear goggles and gloves, because it burns.
- Silver salts are poisonous and stain. Avoid contact and dispose of waste as directed.
- Glassware can break. Keep it away from the bench edge.
Calculation: Ag⁺ + I⁻ → AgI(s); Ag⁺ + SCN⁻ → AgSCN(s). n(I⁻) = n(Ag⁺ added) − n(SCN⁻ titrated). The AgI precipitate doesn't need filtering because AgI is less soluble than AgSCN.
Evaluation: Titrate to a persistent colour. A blank or standardised thiocyanate improves accuracy. The silver nitrate is sensitive to light, so store it in the dark.
Experiment 28 – Colourimetry and calibration curve (copper(II) sulfate)
Syllabus: Conduct investigations to determine the concentration of coloured species and/or metal ions in aqueous solution using colourimetry.
Aim: To determine the concentration of an unknown copper(II) sulfate solution using a calibration curve.
Hypothesis: Absorbance will increase linearly with concentration, so the unknown can be determined from a calibration curve.
Variables: Independent: concentration of CuSO₄. Dependent: absorbance. Controlled: wavelength, same cuvette and orientation, volume (10 mL), temperature.
Method
- Collect about 35 mL of 1.0 mol L⁻¹ CuSO₄ in a 50 mL beaker.
- Fill a clear container or cuvette with 10 mL and measure the absorbance with the colourimeter or light meter. Zero it with distilled water first.
- Measure 8 mL of 1.0 mol L⁻¹ CuSO₄ into a 10 mL measuring cylinder, make up to 10 mL with distilled water (0.8 mol L⁻¹), and measure the absorbance.
- Repeat for 6, 4 and 2 mL diluted to 10 mL (0.6, 0.4 and 0.2 mol L⁻¹).
- Measure the absorbance of 10 mL of the unknown.
- Plot absorbance (y) against concentration (x), draw a line of best fit, and read the concentration of the unknown.
Diagram: colourimeter with cuvette and light path, with the dilution series volumes shown.
Risk assessment
- Copper(II) sulfate is harmful if swallowed and irritates the eyes. Wear goggles and wash hands.
- Electrical equipment near liquids is a shock risk. Keep the colourimeter dry and wipe cuvettes before inserting them.
Results and analysis: Beer–Lambert: A = εlc, so A ∝ c (a straight line through the origin). Read the unknown from the graph (interpolation). If the line doesn't pass through the origin, suspect a zero error or a dirty cuvette.
Evaluation: Use dilutions made with pipettes or volumetric flasks (a measuring cylinder is imprecise). Keep the unknown within the calibration range. Avoid extrapolating outside the measured points.
Experiment 29 – Tests for functional groups (C=C, hydroxyl, carboxylic acid)
Syllabus: Conduct qualitative investigations to test for the presence in organic molecules of carbon–carbon double bonds, hydroxyl groups and carboxylic acids.
Aim: To distinguish an alkene, an alcohol and a carboxylic acid, and identify an unknown.
Hypothesis: Bromine water will test for C=C, acidified dichromate for hydroxyl groups, and sodium carbonate for carboxylic acids.
Variables: Independent: the sample (known compounds and unknown). Dependent: colour change or gas. Controlled: 2 mL of sample, reagent volumes, water-bath temperature.
Method
- Test known samples first: an alkene (cyclohexene), a carboxylic acid (ethanoic acid), and primary, secondary and tertiary alcohols (1-butanol, 2-butanol, 2-methyl-2-propanol).
- Alkene: add 1 mL of bromine water to 1 mL of sample and shake. Decolourisation means C=C.
- Carboxylic acid: add 2 mL of 0.1 mol L⁻¹ Na₂CO₃ to 2 mL of sample. Fizzing (CO₂) means –COOH.
- Hydroxyl: warm 2 mL of sample with 1 mL of acidified dichromate in a hot-water bath (about 70°C). Orange → green means a primary or secondary alcohol; no change suggests a tertiary alcohol (or no –OH).
- Apply these tests to the unknown and use a flow chart to justify its class.
Diagram: a flow chart showing tests and results, and a test-tube rack with the 1–2 mL volumes.
Risk assessment
- Bromine water and dichromate are toxic and corrosive. Use a fume cupboard, gloves and goggles, to avoid skin contact and inhalation.
- Organic liquids are flammable. Keep them away from flames and use a hot-water bath, not a Bunsen.
- Acids and carbonate may splash. Wear goggles.
Results and analysis: Alkene + Br₂ → dibromoalkane (orange to colourless). RCOOH + Na₂CO₃ → RCOONa + H₂O + CO₂. Primary and secondary alcohols are oxidised; tertiary are not. Alcohols that give an acid product can also fizz with carbonate.
Evaluation: Test known compounds first to confirm the tests work. Alkane and alkene reactions with bromine can look alike if the alkane reacts slowly. Dichromate also reacts with other reducing groups.
QUICK EXAM CHECKLIST FOR ANY EXPERIMENT
- Aim and hypothesis that name the variables (not "to prove").
- Independent, dependent and controlled variables with how each is controlled.
- Method steps with equipment, substances and realistic quantities (e.g. 2 mL, 25.00 mL pipette, 100 mL beaker).
- Repeats (e.g. three trials, concordant titres within 0.10 mL).
- Risk assessment: hazard → precaution → why.
- Labelled diagram in pencil with a ruler, showing the substances and quantities.
- Results format: a table with units and headings, a graph if there is a relationship.
- Analysis: balanced equations, calculations with significant figures, Le Chatelier or collision theory explanations.
- Evaluation: sources of error, reliability, validity, accuracy, and a specific improvement.